MIL-PRF-62048C
listed in table II. The sequence of tests to be performed on individual elements must be per table
II. The order of elements to be tested may not necessarily follow the sequence listed.
4.3 Conformance inspection. Conformance inspection shall include the examinations of
4.4 and the tests of 4.5.
4.4 Examination. Each air cleaner assembly shall be examined for compliance with the
requirements specified in 3.2 through 3.6. Any redesign or modification of the contractor's
standard product to comply with specified requirements, or any necessary redesign or
modification following failure to meet the specified requirements shall receive particular
attention for adequacy and suitability. This element of inspection shall encompass all visual
examinations and dimensional measurements. Noncompliance with any specified requirements
or presence of one or more defects preventing or lessening maximum efficiency shall constitute
cause for rejection.
TABLE I. Classification of inspections.
See table II for sequence of tests.
7