F-F-351F
standard production item is submitted, the item must meet the requirements of the specification
and must be representative of the design, construction, and manufacturing technique applicable to
the remaining items to be furnished under the contract (see 6.2 and 6.3).
TABLE IV. Classification of defects.
Methods
Category
Defect
of examination
Major:
101
Dimensions not within specified tolerance for proper installation
SIE 1/
or operation (see figure 1 and applicable specification sheets).
102
Design not as specified. Any component or part missing,
Visual
damaged, deformed, or not as specified (see 3.4, 3.5, and 3.6).
103
Installation arrangements (fastening or mounting) missing,
Visual
defective, or not as specified (see 3.4.1.6).
Visual
104
Pullout device, gasket, or sealing member (as applicable)
missing, defective, or not as specified (see 3.4.1, 3.4.2 and
3.4.3 as applicable).
Minor:
201
Finish missing, improper, or not as specified (see 3.4.1).
Visual
202
Identification and/or marking, missing, illegible, incomplete,
Visual
incorrect, not permanent, or not as specified (see 3.6.1
through 3.6.4).
1/ = Standard Inspection Equipment
TABLE V. Verification table.
Type I
Type II
Type IV
Class
Class
Class
Title
Requirements
Verification
1
3
1
3
1234
Pressure resistance
3.5.1
4.6.1
X
X
Media migration
3.5.2
4.6.2
X
X
X
X
XX
X
X
Antidrain-back device
3.5.3
4.6.3
X
X
Additive removal
3.5.4
4.6.4
X
X
X
X
X
Filtering ability
3.5.5
4.6.5
X
X
X
X
X
X
X
X
Shock resistance
3.5.6
4.6.6
X
X
X
X
X
X
End load strength
3.5.7
4.6.7
X
X
X
X
Differential pressure
3.5.8
4.6.8
X
X
X
X
Force-cover spring
3.5.9
4.6.9
X
Pull-out device
3.5.10
4.6.10
X
X
X
tension
11