F-F-351F
"HEAVY DUTY SENIOR SIZE FILTER ELEMENT." If the marking is placed on the side, the
word "TOP", together with one or more arrows pointing to the top of the element shall be added.
3.6.4 Type IV. For type IV elements, the elements shall be plainly and permanently
marked. Marking shall include the words "FULL FLOW OIL FILTER ELEMENT" as well as
the element class, National Stock Number, manufacturer's name or trademark, and the
manufacturer's part number.
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise specified in the contract, the
contractor is responsible for the performance of all inspection requirements (examinations and
tests) as specified herein. Except as otherwise specified in the contract, the contractor may use
his own or any other facilities suitable for the performance of the inspection requirements
specified herein, unless disapproved by the Government. The Government reserves the right to
perform any of the inspections set forth in this specification where such inspections are deemed
necessary to assure that supplies and services conform to prescribed requirements.
4.1.1 Responsibility for compliance. All items shall meet all requirements of section
3 and 5. The inspection set forth in this document shall become a part of the contractor's overall
inspection system or quality control program. The absence of any inspection requirements in this
document shall not relieve the contractor of the responsibility of ensuring that all products and
supplies submitted to the Government for acceptance comply with the requirements of the
contract. Sampling inspection, as part of manufacturing operations is an acceptable practice to
ascertain conformance to requirements, however, this does not authorize submission of known
defective material, either indicated or actual, nor does it commit the Government to accept
defective material.
4.1.2 Component and material selection. Components and materials shall be inspected in
accordance with all the requirements specified herein and in applicable referenced documents.
4.2 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.3).
b. Conformance inspection (CI) (see 4.4).
4.3 First article inspection. When a first article is required (see 3.2, 6.2 and 6.3), the
sampling method and sample number of filters and/or filter elements of each type to be
manufactured, shall be as stated in the contract. The sample(s) shall be examined for the defects
specified in table IV and shall be subjected to the inspections specified in table V. Failure of any
filter or filter element to pass any of these inspections shall be cause for non-acceptance. If a
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business