INCH-POUND
MIL-PRF-62284B(AT)
09 November 2009
SUPERSEDING
MIL-PRF-62284A(AT)
18 December 1997
PERFORMANCE SPECIFICATION
BLOWER ASSEMBLY, AIR CLEANER
This specification is approved for use by the U.S. Army Tank-automotive and Armaments
Command, Department of the Army, and is available for use by all Departments and
Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers a 1/10 horsepower (hp) continuous duty motor
directly coupled to a 60 standard cubic feet per minute (stdft3/min) blower, operating from an
18 to 30 Volts direct current (Vdc) power source.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this
specification. This section does not include documents cited in other sections of this
specification or recommended for additional information or as examples. While every effort has
been made to ensure the completeness of this list, document users are cautioned that they must
meet all specified requirement documents cited in sections 3 and 4 of this specification, whether
or not they are listed.
Comments, suggestions, or questions on this document should be addressed to U.S. Army
Tank-automotive and Armaments Command, ATTN: RDTA-EN/STND/TRANS, MS# 268,
6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to
DAMI_STANDARDIZATION@conus.army.mil. Since contact information can change, you
may want to verify the currency of this address information using the ASSIST Online database at
https://assist.daps.dla.mil.
AMSC N/A
FSC 2940
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business